European Technology

CID510: high standards of performance and safety

Performance and safety

Public administrations are always looking for innovative solutions to improve the efficiency of their services and reduce their environmental impact. In the context of public agencies, where fuel quality and reliability are crucial to ensure the proper operation of public vehicles and emergency equipment, the CID 510 emerges as an essential resource to ensure high standards of performance and safety. 

The CID 510 is the state-of-the-art analyzer that allows you to precisely control the cetane number of your Diesel or Biodiesel fuels, ensuring optimal performance and reducing environmental impact.

CID 510, Cetane Ignition Delay

Analyzer for determination of cetane number

Herzog's Cetane Ignition Delay CID 510 from PAC is an advanced instrument for measuring the cetane number in diesel fuels, with key benefits for diesel engine operation:

Accurate measurement

It ensures that fuels meet the quality and performance standards required for critical operations. It is approved as standard ASTM D7668 and EN 16715, which confirms the accuracy of its measurements.

Reliability and intuitive operation

Rigorous testing ensures consistent and reliable results over time. Designed to be easy to use, it enables operators to get results quickly and without complications.

Economic benefits

The CID 510 is significantly more affordable than traditional systems, with a lower initial cost and minimal operating costs. It requires little bench space and no separate room, optimizing the use of resources and space in public laboratory environments

The CID 510 is certified to ASTM D7668, ISO EN 16715 standards, correlated with ASTM D 613, ensuring that cetane number measurements meet the most stringent international standards.

Certifications of Excellence for CID 510

This combination of certifications ensures that every measurement made with the CID 510 not only meets but exceeds the most stringent international standards, providing reliable and consistent results that can be used to ensure fuel quality in the most demanding environments.

For government agencies and other institutions involved in fuel management, these certifications offer assurance of compliance and accuracy, ensuring that fuels tested with the CID 510 meet international regulations and help maintain high standards of quality and operational safety.

Certifications of Excellence for CID 510

This combination of certifications ensures that every measurement made with the CID 510 not only meets but exceeds the most stringent international standards, providing reliable and consistent results that can be used to ensure fuel quality in the most demanding environments.

For government agencies and other institutions involved in fuel management, these certifications offer assurance of compliance and accuracy, ensuring that fuels tested with the CID 510 meet international regulations and help maintain high standards of quality and operational safety.

Why choose CID 510?

Impeccable accuracy

It provides an accurate measurement of derived cetane number (DCN), which is critical to the quality and efficiency of diesel and biodiesel fuels.

Ideal for advanced fuels

Perfect for biodiesel and blends with cetane number improvers. Overcomes the limitations of traditional methods such as CFR and CVCC.

Common rail injection system

High precision with pressures up to 1500 bar, ensuring complete volatilization and soot-free combustion.

Combustion chamber

Optimized to clearly observe pre-flame reactions and the effects of cetane improvers.

Advanced and exclusive design

Common rail injection system

The modern high-pressure (up to 1500 bar) common rail injection system ensures complete volatilization of the sample and soot-free combustion. This advanced technology allows for more precise and repeatable results, which are critical for accurate fuel quality assessment.

Combustion Chamber

The combustion chamber with multi-nozzle high-pressure injector allows for clear observation of pre-flame reactions and the effects of cetane improvers such as 2-ethylhexylnitrate (EHN), providing a better understanding of combustion processes.

Automatic calibration and diagnostics

Automatic diagnostic functions and automatic calibration reduce the risk of downtime, ensuring reliable performance and minimizing the need for manual intervention.

Features and Benefits

The Cetane Ignition Delay CID 510 is a compact and easy-to-use analyzer with fully automatic analysis and calibration sequences, offering analysis with extremely high accuracy.

International Certifications

Compliance with ASTM D7668 and ISO EN 16715.

Fast and accurate analysis

Enables detailed and accurate analysis of derived cetane number for diesel fuels, increasing laboratory efficiency and productivity.

One-button operation

Enables fully automatic one-button testing, optimizing analysis time and facilitating daily use.

Superior performance

Outperforms results obtained with the CFR Engine and other CVCC methods, with no carryover effects from previous samples.

Long-term stability

Automatic calibration and diagnostic features reduce the risk of downtime and ensure reliable performance over time.

Compact design

Requires minimal workbench space, facilitating integration into various laboratory environments.

High safety

Includes built-in fire monitoring, overpressure protection and an advanced suppression system to ensure safe operation.

Reduced costs

- Lower initial investment (2 times less expensive than traditional systems).
- Low operating costs and minimal maintenance.

The CID 510 is designed to offer derived cetane analysis with unmatched accuracy, ideal for critical laboratory needs and perfect for applications in high-demand environments.

European Technology is your ideal partner for advanced analytical instruments, ensuring technology solutions that meet the unique challenges of the defense industry.

European Technology is your ideal partner for advanced analytical instruments, ensuring technology solutions that meet the unique challenges of the defense industry.

Contact us to find out how our instruments can optimize your operations and improve laboratory results.

Fill out the form: you will be contacted by one of our sales people.

*Read the Privacy Policy

Product added to compare.